Slant/Fin Error Lockout 109 / Hold 110: Ignition failure — failed to prove flame after 3 attempts

The control attempted ignition three times and never proved a stable flame, so it locked out (Lockout 109; Hold 110 = ignition failure occurred during a recycle-and-hold). The Slant/Fin CHS manual lists these documented causes: a disconnected high-voltage spark cable, a disconnected flame-rod signal wire, blocked venting (exhaust-vent, air-inlet, combustion blower, gas-valve venturi, or heat exchanger), insufficient gas line pressure (manual gas valve closed or low supply pressure), no 120VAC to the spark generator, a faulty spark generator, no 24VAC to the gas valve, or a faulty gas valve. (The manual does not specify an electrode gap dimension.) We diagnose and repair it across Greater Vancouver — same-day and after-hours.

What Slant/Fin Error Lockout 109 / Hold 110 Means

The control attempted ignition three times and never proved a stable flame, so it locked out (Lockout 109; Hold 110 = ignition failure occurred during a recycle-and-hold). The Slant/Fin CHS manual lists these documented causes: a disconnected high-voltage spark cable, a disconnected flame-rod signal wire, blocked venting (exhaust-vent, air-inlet, combustion blower, gas-valve venturi, or heat exchanger), insufficient gas line pressure (manual gas valve closed or low supply pressure), no 120VAC to the spark generator, a faulty spark generator, no 24VAC to the gas valve, or a faulty gas valve. (The manual does not specify an electrode gap dimension.)

Slant/Fin fault codes can vary by model and series. Use this as a guide — the same code can have more than one cause. Our Technical Safety BC–licensed technicians read the code, confirm it against your unit's manual, and diagnose the true cause before any repair.

Likely causes of Slant/Fin error Lockout 109 / Hold 110

  • Incorrect spark igniter electrode gap or faulty/dirty igniter
  • Disconnected spark cable or igniter ground wire
  • Insufficient gas supply (manual gas valve closed or low gas pressure)
  • Blocked exhaust vent, air intake, blower, gas-valve venturi, or heat exchanger
  • Disconnected flame rod, faulty gas valve, or no spark from the spark generator

What you can safely check

  • Confirm the manual gas shutoff valve to the boiler is fully open and other gas appliances work
  • Check that the outside exhaust and intake vent terminals are not blocked

Beyond these checks, do not open the unit or touch gas/electrical parts — BC law requires a licensed gas fitter. Call us for a proper diagnosis.

Error Lockout 109 / Hold 110 usually leaves you without heat or hot water and can indicate a safety-related fault. Don't keep resetting it — call for priority after-hours Slant/Fin repair.

Parts Are Professionally Installed — Not Sold for DIY

For your safety and to keep your manufacturer warranty valid, BoilerPart.ca does not sell loose boiler parts over the counter or for self-installation. Under BC regulations, gas appliance components must be installed by a licensed gas fitter. Every part we source is genuine OEM and is professionally fitted, tested, and certified by our Technical Safety BC–licensed technicians as part of a complete repair or installation.

Parts often behind Slant/Fin error Lockout 109 / Hold 110

Genuine Slant/Fin parts we supply and professionally install — never for DIY.

Our Guarantees & Warranties

Every repair and installation is backed by genuine parts, licensed workmanship, and a promise to make it right.

Workmanship Guarantee

Every repair and installation is backed by our written workmanship guarantee. If a part we installed fails because of our work, we make it right.

Genuine OEM Parts

We fit only manufacturer-original (OEM) components so your boiler performs to spec and keeps its factory warranty intact.

Manufacturer Warranty Honoured

As an authorised service provider for the brands we work on, our installs preserve and register your manufacturer parts warranty.

Licensed & Insured

All work is completed by Technical Safety BC–licensed gas fitters (Licence LGA0043870, Boiler Permit LBP0046450). We are fully licensed, bonded and insured for your protection.

Up-Front Pricing

You approve the diagnosis and quote before any work begins. No hidden fees and no surprise charges.

Satisfaction Commitment

Backed by the full HVAC resources of CanroHeat.ca and four decades of service in Greater Vancouver since 1985.

Frequently Asked Questions

Fix Slant/Fin Error Lockout 109 / Hold 110 Today

Licensed Slant/Fin diagnosis and repair with genuine parts — same-day and after-hours across Greater Vancouver.

A Division of CanroHeat.ca · Licensed Gas Fitters · Serving Greater Vancouver since 1985

Call NowSame-Day Service